Span Gas Value x Factor x = Calibration value (in VDC) (+/- 3 % of the scale) Full scale VA201T/M CALIBRATION INFORMATION - Q1 Sensor Gas (Q1) Sensor VA201T Scale VA201M Scale Warm-Up Factor Zero Pot Span Pot Flow Rate L/min Notes CL2 SCL2-7CLH SCL2-S7 ppm 15 ppm 5 min. - - 2 CO SCO-4BW 0 - 255 ppm 0 -250 ppm 5 min. - - 2
• Replace sensor. 32 Outgoing Water Temperature Sensor Fault • Check sensor wiring for damage. • Measure resistance of sensor. • Clean sensor of scale build up. • Replace sensor. 33 Heat Exchanger Outgoing Temperature Sensor Fault • Check for restrictions in air flow around unit and vent terminal. • Check sensor wiring for damage.
Prior to each day’s use, every gas detection monitor should be bump tested to confirm the response of all sensors and activation of all alarms by exposing the monitor to a concentration of target gas that exceeds the low alarm set point. A bump test is also recommended if the monitor has been subjected to physical performance is in doubt. To ensure greatest accuracy and safety, only bump ...
Übersetzer. Nutzen Sie die weltweit besten KI-basierten Übersetzer für Ihre Texte, entwickelt von den Machern von Linguee. Linguee. Finden Sie verlässliche Übersetzungen von Wörter und Phrasen in unseren umfassenden Wörterbüchern und durchsuchen Sie Milliarden von Online-Übersetzungen.
A sensor that cannot be calibrated or is found to be out of tolerance must be replaced immediately. An instrument equipped with a toxic gas sensor that fails calibration may not be used until testing with known concentration test gas determines that accuracy has been restored, and the instrument is once again fit for use. Instruments equipped ...
Sensepoint Combustible PPM Gas Sensor ATEX CE EU Declaration of Conformity. KB. 7/15/2021. PDF KB. Sensepoint Flammable Gas Detector Manual. Sensepoint Flammable Gas Detector Manual. KB. 7/15/2021. PDF KB. Unipoint Gas Sensing Controller Atex EC Type-Examination Certificate. Unipoint Gas Sensing Controller Atex EC Type-Examination Certificate …
5 – Replace Gas Valve This indicates a sensor failure and the gas control valve must be replaced. 7 – Replace Gas Valve Overall failure of the gas valve and will usually require replacement. If you get this code and have lukewarm water and the pilot is still on, try turning up the temperature. This has happened to us twice and both times ...
the remote sensor must be securely mounted in a fixed position. The Remote Sensor kit is not intended to be used as a hand-held sensor. • Enclosures of remotely mounted sensors contain aluminum. Be careful to avoid ignition hazards due to impact or friction when installed in Zone 1 locations.
Honeywell Analytics gas sensor technologies. XNX Universal Transmitter XNX is an extremely flexible transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies. It can also be configured to provide a wide variety of industry standard output signals. This enables users to have a single type of interface to all their gas detection ...
the sensor and the gas. When there is no heat transfer, the measurement system is in thermal equilibrium and the sensor is as close to the gas temperature as it will get. In reality, the sensor temperature will never be the same as the gas temperature due mainly to conduction errors. Figure 1. Typical sensor installation including thermowell and
Table 1. lists the gases monitored. Zeroing the Sensors To zero the sensors, refer to steps #1-3 in Connecting to the IR Link. Table 1. Gases Monitored Gas Detected Unit of Measure Hydrogen sulfide (H2S) parts per million (ppm) Carbon monoxide (CO) parts per million (ppm) Oxygen (O2) percent by volume (%) Combustible gases (LEL) Field selectable for: 1. percent of lower explosive limit (% LEL ...
Replace the supply and return sensor C Y 241 The return sensor contact is interrupted 6 A 227 No ionization after four startup attempts Contact the gas utility company to ensure that no nitrogen remains in the gas tank or gas supply pipes. Bleed the gas supply pipe. Replace the hot surface ignitor. Adjust the gas/air ratio. Fit the correct gas orifice. Clean and/or replace the corresponding ...
· Directly related to the issue of noise is the challenge of gas void fractions or dual-phase flow. Dual-phase flow is a condition that occurs when there is gas (or voids) entrained in liquid flows or when there is liquid dispersed within a gas flow. Initially, Coriolis sensors were susceptible to errors when flowing a dense liquid, such as water, entrained with slugs of lightweight air. When ...
thermostat well sensor fault reset. 6 enero, 2021 | In Sin categoría | By ...
1. Flammable vapor sensor resistance is out of range (well below or well above parameters) 2. Wiring to FV sensor is faulty (open) 3. Gas control is faulty 1. Verify FVS sensor resistance ~ 9K -45 K 2. Replace sensor and wiring harness. 3. Replace control if new sensor does not work.
Temperature sensors: Supply sensor open or shorted Return sensor open or shorted. Set if flue sensor not balanced (more than 10 °F difference between sensors) Set if heat exchanger outlet sensor not balanced (more than 10 °F difference between sensors) Reset if sensors balance: Flue temperature high: Set if flue temperature over 210 °F: Reset after minute delay: LWCO fault: Set if 1WCO ...
NDIR-Sensoren für die gängigsten Gase. Unter dem Motto Blue Performance präsentiert Smartgas auf der Sensor+Test Gas-Sensoren die jüngste Generation von NDIR-Sensoren für die Messung halogenierter Kohlenwasserstoffe zur Lecksuche bei Kälte- und Klimaanlagen.